The GCL GCL-M3/60 330 photovoltaic panel offers a power of 330W. The maximum current is 9.76A, with a voltage of 33.8V. The panel shows resilience with 10.2A short circuit current and 40.44V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-M6/60 310 Cast Mono photovoltaic panel offers a power of 310W. The maximum current is 9.46A, with a voltage of 32.8V. The panel shows resilience with 9.96A short circuit current and 39.9V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-M6/72 365 photovoltaic panel offers a power of 365W. The maximum current is 9.31A, with a voltage of 39.2V. The panel shows resilience with 9.89A short circuit current and 47.6V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-P6/60 295 photovoltaic panel offers a power of 295W. The maximum current is 9.1A, with a voltage of 32.4V. The panel shows resilience with 9.74A short circuit current and 40V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-P6/72 360 photovoltaic panel offers a power of 360W. The maximum current is 9.56A, with a voltage of 37.66V. The panel shows resilience with 10.1A short circuit current and 46.81V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-M3/60 335 photovoltaic panel offers a power of 335W. The maximum current is 9.81A, with a voltage of 34.16V. The panel shows resilience with 10.24A short circuit current and 40.71V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-M6/60 310 MBB photovoltaic panel offers a power of 310W. The maximum current is 9.46A, with a voltage of 32.8V. The panel shows resilience with 9.96A short circuit current and 39.9V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-M6/72 370 photovoltaic panel offers a power of 370W. The maximum current is 9.39A, with a voltage of 39.4V. The panel shows resilience with 9.97A short circuit current and 47.8V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-P6/60 300 photovoltaic panel offers a power of 300W. The maximum current is 9.2A, with a voltage of 32.6V. The panel shows resilience with 9.79A short circuit current and 40.3V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-P6/72 365 photovoltaic panel offers a power of 365W. The maximum current is 9.1A, with a voltage of 40.11V. The panel shows resilience with 9.86A short circuit current and 48.5V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-M3/72 380 Cast Mono photovoltaic panel offers a power of 380W. The maximum current is 9.29A, with a voltage of 40.9V. The panel shows resilience with 9.79A short circuit current and 48.34V open circuit voltage, indicators of safety in adverse conditions.
The GCL GCL-M6/60 315 Cast Mono photovoltaic panel offers a power of 315W. The maximum current is 9.55A, with a voltage of 33V. The panel shows resilience with 10.04A short circuit current and 40.1V open circuit voltage, indicators of safety in adverse conditions.